Dutch Startup Asperitas Launches
  • What is a modular optical port

    What is a modular optical port

    An optical port is a physical interface used to connect fiber optic cables. Currently, mainstream optical modules include SFP and QSFP form factors, with transmission rates ranging from 2M to 100G. Optical modules typically have an electrical interface on the side that connects to the inside of the system and an optical interface on the side that connects to the outside. The optical module serves as a crucial component in optical fiber communication systems, operating at the physical layer, which is the lowest layer in the OSI model. Its primary function is to achieve optoelectronic conversion by converting electrical signals into optical signals and vice versa. Operating at the physical layer of the OSI model, optical modules are core devices in optical. What is an Optical Module? The Ultimate Guide to Principles, Types, and Troubleshooting Optical Modules (also known as Optical Transceivers) are critical components in fiber optic communication systems.

    [PDF Version]
  • Professional Modular Core Switch

    Professional Modular Core Switch

    This is the next generation of modular Gigabit and Multigigabit Ethernet switches. The series provides enterprise-class Layer 2 and 3 switching, is designed for DNA Center and SD-Access management and automation, and includes an Enhanced Limited Lifetime Warranty (E-LLW). Looking for a. The QFX10000 line of modular data center spine and core Ethernet switches delivers industry-leading scale, flexibility and openness, with a design that enables the seamless transition from 10GbE and 40GbE interface speeds to 100GbE in data center and campus deployments. 4 billion in 2023 and is expected to reach US$ 24. Similarly, the high-density frame core switch market was valued at US$ 3. 4 billion by. EVI is a MAC-in-IP technology that provides Layer 2 connectivity between distant Layer 2 network sites across an IP routed network.

    [PDF Version]
  • Dutch OSFP optical module 400G

    Dutch OSFP optical module 400G

    The Lumentum 400ZR module on an OSFP form factor is designed for use by hyperscale data center operators and peering networks to provide high bandwidth interconnections in an industry standa.


  • Materials for Dutch Fireproof Cable Trays

    Materials for Dutch Fireproof Cable Trays

    Fireproofing Measures for Cable Trays Galvanized steel,Stainless steel,Fire-resistant coated trays,Flame-retardant plastic composites. There are several material choices available for cable trays in today's market, the most popular choices are steel (HDG/SS), aluminum, PVC and FRP/GRP. However, there is not a common consensus on how these material types compare to each other in fire conditions. So, we put them to test! Take a look. Fire safety and fire resistance are vital part of responsible electrical designing and installation. Meka Pro has tested and continues to test its products and cable management systems´ fire resistance with the cables installed and connected according to the temperature curve in the EN 1363-1. Fire resistance is a key factor when selecting cable trays for areas where fire hazards are present. Materials like steel. FyreWrap® Cable Insulation from Alkegen is a thin, flexible insulation wrap designed to provide fire protective enclosures around cable trays and conduit.

    [PDF Version]
  • Immersion Liquid Cooling for Computer Rooms in Intelligent Buildings

    Immersion Liquid Cooling for Computer Rooms in Intelligent Buildings

    Immersion cooling involves submerging IT hardware in dielectric fluid that does not conduct electricity. Heat generated by the components is transferred directly into the liquid, which is then circulated and cooled. Single-Phase Immersion Servers are submerged in a bath of liquid. Data center immersion cooling (or “liquid immersion cooling”) is an energy-efficient option that offers superior cooling for high-density workloads. Advanced AI chips are generating more heat in data centers, necessitating improved cooling solutions. Data Center. For decades, air cooling has been the standard for data centers. Rows of CRAC units, raised floors, and hot-aisle/cold-aisle containment kept servers running. But in 2025, that model is under pressure. The rise of AI workloads, GPU clusters, and high-density racks is straining the limits of air. It is a system and an ecosystem comprising various components such as Coolant Distribution Units (CDUs), cold plates, manifolds, liquid-cooled servers, heat rejection units, and complementary air-cooling components.

    [PDF Version]
  • Manufacturer of anti-vibration server racks with immersion liquid cooling

    Manufacturer of anti-vibration server racks with immersion liquid cooling

    High-density, liquid-cooled, rack-based servers for data centers, edge computing, and harsh environments. LiquidCool Solutions is the only company combining Total Liquid Immersion with Directed Flow (direct-to-chip) in a standard 19″ rack. Because liquid cools 1,000x better than air, we can provide. The DCX Facility Distribution Unit (FDU) is a centralized coolant distribution unit used in direct liquid cooling systems for large-scale server clusters, including GPU-intensive environments. It is installed outside the white space, engineered to serve entire data halls. It replaces dozens of. Flex's OCP ORv3-inspired liquid-cooled systems are designed to support the most demanding artificial intelligence (AI) and high-performance computing (HPC) workloads, efficiently cooling up to 120kW per rack and beyond. Optimize your operational costs, reduce your environmental and physical footprint, and deploy faster than the competition.

    [PDF Version]
  • Liquid Crystal Optical Module

    Liquid Crystal Optical Module

    Liquid crystal modulators are a type of optical modulator which utilize liquid crystals to control the intensity, phase, or polarization of light. The operation principle is based on the birefringence of liquid crystals, where long molecules align to create anisotropic optical properties. Its key features include WUXGA (1920 x 1200) high resolution, 10-bit (1024 levels) phase resolution, and phase stability of less. Spatial light modulators, as dynamic flat-panel optical devices, have witnessed rapid development over the past two decades, concomitant with the advancements in micro- and opto-electronic integration technology. In particular, liquid-crystal spatial light modulator (LC-SLM) technologies have been. Liquid crystal on silicon (LCoS or LCOS) is a miniaturized reflective active-matrix liquid-crystal display or "microdisplay" using a liquid crystal layer on top of a silicon backplane. It is also known as a spatial light modulator. The head has an address section where laser light enters and the controller connects to a PC via a DVI (digital video interface).

    [PDF Version]
  • Telecom launches Silk Road optical cable

    Telecom launches Silk Road optical cable

    This strategic project involves the construction of a 380 km-long fiber-optic cable line across the Caspian Sea, connecting Sumgayit (Azerbaijan) and Aktau (Kazakhstan). It will provide high-capacity data transmission, enabling high-speed internet connectivity of up to 400 terabits. NEQSOL Holding announces the successful completion of tender procedures and the launch of the first phase of construction for the Trans-Caspian Fiber Optic Cable Line, a key component of the “Digital Silk Way” megaproject initiated by the Holding. This landmark project, a core component of the Digital Silk Way initiative, is being.